Quick filter
10th International Hybrid Power Plants & Systems Workshop 2026
Sardinia, Italy, 05–06 May 2026
Integrating Renewable Energy Systems on German Dairy Farms: Validation of Simulation-Based Energy Management, Sizing, and Exploration of Future Energy-Production Pathways
Lea von Rüden, Nies Reininghaus, Michael Kröner, Martin Vehse, Alexander Dyck
German Aerospace Center (DLR), Institute of Networked Energy Systems, Germany
Farming is a crucial sector to support the transformation towards a net zero energy system as they have space for renewable energy installations and important resources such as manure. Multiple simulations have been carried out, assessing potentials for renewable energy integration on dairy farms. However, a thorough validation of those simulations is lacking. This study examines how closely the presented simulation tool can represent the reality for a case study based on a Northern German farm and further advances the simulation regarding possible expansions. The PV simulation with PVlib is based on strongly localised weather data, leading to differing cloud covers and thereby a deviation between simulation and measurement data. The deviations are much smaller for the biogas production compared to the deviation of the PV simulation, as the biogas production is very steady, and closely related to the manure availability. The possibilities for future, further usage of the biogas / the PV produced energy are simulated, including, direct biogas usage as fuel, hydrogen production though electrolysis and biogas reforming. The simulation shows, that all three options assessed are possible for the self-sufficient fuel production. However, the option of biogas as fuel accounts for the best energy usage with little losses.
Topic/s:
B2-Project Experience and Case Studies
Residual Load Dynamics in Electrified Neighbourhoods: The Role of Heat Pumps, BEVs, Rooftop PV, and Regulatory Load Control
Robert Otto, Janine Singer, Carmen Giehl, Eric Duminil, Bastian Schröter
Hochschule für Technik Stuttgart Schellingstraße 24 70174 Stuttgart, Germany
The increasing electrification of heating and mobility is fundamentally reshaping load patterns in electricity distribution net-

works. The integration of heat pumps, rooftop PV, and BEVs introduces challenges due to temporally concentrated load and

feed-in peaks. This paper presents an integrated modelling approach to generate building-resolved load profiles at district level,

considering technology diffusion up to 2045. Based on building simulations, mobility data, and thermodynamic modelling,

hourly residual load profiles are derived for multiple scenarios, including uncontrolled operation and grid-oriented control via

regulatory load limitation of controllable consumers (according to §14a EnWG). Results show that peak loads increase by a

factor of 2.4 between 2030 and 2045 under uncontrolled conditions, while the average residual load increases only moderately

in comparison. Critical situations mainly result from the temporal coincidence of heat pump operation and BEV charging. Reg-

ulatory load limitation reduces peak loads by only 3–11 % and overload hours by 13–23 %, leaving substantial grid constraints,

especially in highly electrified scenarios. At the same time, PV feed-in peaks become increasingly relevant. The findings indicate

that regulatory measures alone are insufficient to ensure long-term grid stability and underline the need for integrated assessment

approaches.
Topic/s:
B3-System Modelling and Simulation
Operational Implementability of Time-Limited MILP-Based Energy Management in Hybrid Power Systems
Lukas Peter Wagner, Vincent Henkel, Lasse Matthias Reinpold, Felix Gehlhoff
Helmut Schmidt University Hamburg, Germany
Hybrid power systems combine volatile renewable energy generation with controllable conversion and storage units, requiring operational planning that respects both system dynamics and resource operating limits. This work studies how time-limited mixed-integer linear programming (MILP) for energy management affects schedule quality and physical implementability, treating temporal resolution, optimality gap threshold, and computational deadline as explicit design parameters. A 24 h planning problem is solved across five temporal resolutions, including sub-15-minute steps, under varying gap thresholds and time cutoffs. Time-limited solutions are compared to globally optimal schedules of the same planning model, and all schedules are evaluated offline against a mechanistic electrolysis model that captures electrochemical dynamics and operational constraints beyond the MILP abstraction. The results show that discretization error is small while solver times span nearly five orders of magnitude, that loose gap thresholds risk premature termination producing structurally different schedules, and that jointly selecting resolution and gap threshold enables near-optimal quality well within practical computation budgets. The findings highlight computational latency and mechanistic validation as central considerations for operational planning in hybrid power plants.
Topic/s:
B3-System Modelling and Simulation
Strategies to Minimize the Impact of Transformer Inrush Currents in Inverter Driven Island Grids
Till Garn1, Tobias Weinmann2, Konstantin Wagner3, Michael Finkel2, Georg Kerber3, Bernd Engel1
1 TU Braunschweig elenia Institute for High Voltage Technology and Power Systems, Germany
2 Technische Hochschule Augsburg Faculty of Electrical Engineering, Germany
3 Hochschule München Institute for Sustainable Energy Systems, Germany
In this paper the effect of different transformer inrush mitigation strategies that were tested in a field measurement campaign are presented. These mitigation strategies include changes in the parameterization, different voltage ramp up times during the blackstart of the island grid - commonly referred to as soft energisation - and altering the tap changer positions of the transformers. Furthermore, additional scenarios of inrush currents are investigated. These include the magnetisation of transformers over a 9 km long cable and sympathetic inrush currents. The results of these scenarios are analysed by looking into the behaviour of the amplitude as well as the harmonics of the voltage, to accurately describe the reasons for the shutdown of the inverters during transformer inrush. To conclude the paper, the effectiveness of the proposed solutions is discussed and recommendations for dealing with inrush currents in island grids are given.
Topic/s:
A2-Project Experience and Case Studies
Price-Responsive and Resilient Operation of a Modular Electrolysis Plant: Results from a Laboratory Demonstrator
Vincent Henkel1, Lukas Wagner1, Felix Gehlhoff1, Alexander Fay2
1 Helmut Schmidt University Hamburg, Germany
2 Ruhr University Bochum, Germany
Modular electrolysis plants can provide flexible, price-responsive hydrogen production, but coordinating multiple electrolyzer units under volatile operating conditions and electrolyzer failures remains challenging. This work reports on laboratory experiments with a modular electrolysis plant demonstrator comprising three anion-exchange membrane electrolyzers, operated using a multi-agent real-time optimization approach that minimizes electricity procurement costs on a rolling horizon. Three test cases are evaluated: price-responsive operation under a static demand target, operation under electrolyzer failures, and a combined scenario with demand changes and failures. Across all scenarios, load is shifted toward low-price periods. Under nominal conditions, cumulative production deviates by less than one percent from the target. Under electrolyzer failures, load is redistributed to the remaining units within their admissible operating ranges. The results provide proof-of-concept evidence that modular electrolysis plants, coordinated via standardized interfaces and decentralized optimization, can operate as flexible assets in hybrid energy systems.
Topic/s:
A2-Project Experience and Case Studies
Integrating a Run-of-River Hydroelectric Facility into a Remote Off-Grid System
Jonathan Brisebois
Hydro-Québec, Canada
The village of Inukjuak (~2,000 residents) in northern Québec historically relied on a diesel-only generating station to supply its off-grid electrical system. To reduce greenhouse gas emissions and diesel dependence across Hydro-Québec’s remote systems, the Innavik project demonstrates a viable pathway to high renewable penetration using a run-of-river hydroelectric generating station coupled with coordinated load conversion and advanced control.

Prior to integration, the diesel plant (3,758 kW installed across four units) supplied a peak winter load of ~1,800 kW and ~10,000 MWh annually, with heating predominantly oil-fired for efficiency and cost. The community’s initial energy price proposal for hydro purchase was not commercially viable; however, a strategic ~300% rise in electric demand via heating conversion created sufficient revenue to support a power purchase agreement. Hydro-Québec upgraded the medium-voltage grid from 4.2 kV to 25 kV, and the network was segmented into remotely controllable load blocks so the hydro plant could re-energize blocks autonomously without interim diesel support. Commissioning tests confirmed the hydro plant could restore 1 MW feeder loads without crossing underfrequency thresholds (57 Hz) and return to 60 Hz, validating autonomous block restoration under controlled heating curtailment. A new backup diesel plant (two units at 2,867 kW each) was added with design compromises appropriate to its limited use.

A microgrid controller continuously computes the margin between available hydraulic power (AHP) and total village load (TVL), switching heating sources by wireless command from a central cell tower. Electric heating is enabled when AHP–TVL ≥ 300 kW and curtailed back to oil as the margin approaches 200 kW.

To align tariffs with the dual-energy strategy north of the 53rd parallel—where the first 40 kWh/day match main-grid rates and excess consumption is typically priced ~4.5× higher—a special second-tier rate (~$0.19/kWh in 2022) was implemented for Inukjuak. This rate is equivalent to the cost of heating with oil and is indexed annually to CPI.

Since fall 2023, the hydro facility has supplied the majority of Inukjuak’s energy. During an upstream ice jam in early 2024 that sharply reduced available hydraulic power, the system shifted all dual-energy heating to oil, preserving full system supply from hydro alone and avoiding diesel usage. For 2024, ~97% of customer energy was delivered by hydroelectricity.

The Innavik project in Inukjuak is among the first to bring energy transition to fruition, while also contributing to decreasing the use of fossil fuels for residential heating. By converting heating load to dual energy, the project proponent made it possible to increase the hydroelectric demand enough to make the project viable. Finally, the commissioning tests and the results from the first months of operation of the new run-of-river facility demonstrate that it meets expectations.
Topic/s:
A2-Project Experience and Case Studies
Grid-Forming Storage Systems an Their Contribution to Instantaneous Power Reserve as a Cornerstone of Future Power Systems: Requirements, Certification, and Implementation Status in Germany
Bernhard Schowe-von der Brelie1, Syed Mansoor Ali2, Johannes Döll2
1 FGH Research Association (FGH e.V.), Germany
2 FGH GmbH, Germany
The ongoing energy transition towards high shares of converter-based generation and storage calls for a fundamental shift in power system stability management. Traditional synchronous plants historically provided essential grid-forming functions, such as voltage and frequency stabilization and short-circuit current contribution. With their phase-locked, grid-following behavior, conventional inverter-based systems cannot inherently deliver these system services, creating challenges for a stable, low-inertia network. To address these challenges, German stakeholders have recently advanced two key regulatory frameworks for grid-forming (netzbildende) converters and battery storage integration.

The VDE-FNN “Technical Requirements for Grid-Forming Properties including the Provision of Instantaneous Reserve” provides the first comprehensive national guideline specifying both functional and demonstrative requirements for grid-forming units across voltage levels as a prerequisite to contribute to an upcoming market of momentary reserve power. This guideline defines technical capabilities such as controlled voltage source behavior, provision of instantaneous reserve, and system support functionalities that mirror the stability contributions of synchronous machines. Importantly, it also outlines measurement-based and simulation-based test procedures to support certification and market participation, thereby aligning with the national System Stability Roadmap.

Complementing this, the 4-TSO paper on requirements for grid-forming converters, developed by Germany’s four transmission system operators (ÜNB), articulates a harmonized set of basic and optional grid-forming capabilities. These capabilities, rooted in international studies such as ENTSO-E’s HPoPEIPS report, are classified into mandatory functions essential for safe grid operation and additional features that may be required depending on local grid conditions. It also provides a link to the upcoming unified technical basis in terms of the expected revisions of European network codes and, hence, respective national technical application rules in other European Member States.

This contribution presents an integrated overview of both the technical requirements and the evidence-based compliance mechanisms emerging in Germany for grid-forming inverters and battery storage systems. It examines the state of certification practices according to the FNN regulation for the eligibility of such installations to participate in the newly establised instantanious reserve power market as well as the required simulation studies to proof conformity to the TSO requirements. It discusses practical challenges in demonstrating compliance through tests and modeling, and highlights early certification efforts in the industry. By synthesizing recent regulatory progress and implementation status, the paper elucidates how these frameworks support the broader objective of enabling secure and resilient power system operation with high inverter-based generation.
Topic/s:
B8-Standards, Grid Codes and Grid Code Validation for Hybrid Power PLANTS
A Hybrid Hydro-ESS Simulation Model to Meet FCR-D Requirements
Joel Gerdes1, Christian Ekstrand1, Peiyuan Chen2, Victor Lidskog1, Eddie Eriksson1
1 Solvina AB, Sweden
2 Departement of Electrical Engineering, Chalmers University of Technology, Sweden
In 2023, the technical requirements for frequency containment reserve - disturbance (FCR-D) in the Nordic synchronous area were revised, introducing stricter demands on dynamic response and new stability criteria. Hydropower plants (HPPs) constitute the largest share of FCR-D provision in the Nordic region. However, HPPs exhibit inherent dynamic delays, which may prevent some units from complying with the revised requirements. A hybrid solution with a fast-acting energy storage system (ESS) is therefore proposed to assist the HPP, enabling the hybrid plant to fulfil the requirements for FCR-D. This paper models a Kaplan HPP in Sweden which fails to meet the revised FCR requirements on its own. A dynamic parallel power sharing strategy between the HPP and ESS for primary frequency control within a hybrid power plant is proposed. Both battery energy storage system and supercapacitor energy storage system are considered for the hybrid plant, and the most cost-effective configuration is explored.
Topic/s:
B11-Ancillary Services from Hybrid Power PLANTS
Dynamic Large-Scale Green Hydrogen Production at the Hydrogen Lab Bremerhaven
Anna Heuschmann, Jannes Vervoort, Kevin Schalk
Fraunhofer IWES, Germany
General scope

Green hydrogen as renewable fuel of non-biological origin (RFNBO) is defined in the EU Renewable Energy Directive (REDIII). These requirements must now be met to produce the targeted green hydrogen which provides operators of hydrogen plants an economic perspective. To minimize risks and accelerate the hydrogen market utilizing models, which are validated with reliable data from large scale testing of electrolysers in dynamic conditions, is unavoidable. The Hydrogen Lab Bremerhaven (HLB) collects data from dynamic operation of electrolysers and does research along the entire green hydrogen supply chain.

Main results

Data from operation of the two different electrolysers was collected for various operation scenarios as well as the behavior in dynamic operation scenarios. The electrolysers operate in different load ranges including start-up and shut-down procedures. Data and experience for storage fillings in the low- and high-pressure area were gained with varying use of the three compressors based on their availability. In addition, trailers for hydrogen transport have been filled. Data about the wind forecast and the created prediction of power consumption for the HLB is available just like the actual produced and consumed power of the test field as part of meeting the RFNBO requirements.

Methods

The HLB, built and operated by the Fraunhofer IWES, offers a hydrogen infrastructure that provides a wide range of operating and testing possibilities with two electrolysers (1 MW PEM, 1.3 MW alkaline), a fuel cell, a CHP-plant and associated peripherals such as storage units, trailer filling station and compressors. It can be flexibly expanded with multiple free test pads. One of these test pads is already equipped to function as a desalination test stand for research regarding offshore electrolysis as part of the H2Mare project.

Power can be supplied from the public grid or from existing electrical testing infrastructure like a converter test rig and a 44 MVA grid emulator. These test rigs were designed for wind energy applications and are integrated into the HLB to enable a wide array of real-world test scenarios and various stand-alone grid operating modes. A Power Purchase Agreement ensures the production of green hydrogen in accordance with the currently valid legal framework. The HLB started its test operation in 2023 and since July 2024 it´s fully handed over to Fraunhofer IWES.

Relevance

The set hydrogen targets need an accelerated ramp-up of the green hydrogen industry. With the REDIII closing in to practical applicability and economic relevance a dynamic operation of electrolysers is inevitably necessary. The lack of data of large-scale testing and validated models in this area leads to high risks in project planning and realization which causes many cancellations of hydrogen projects due to uncertain future perspectives.

Major conclusions drawn

The operation of the HLB collects a lot of important data along the green hydrogen supply chain, from the interaction of hydrogen components to individual system data in dynamic operation. Different operation scenarios and dynamic changes of the units are recorded, and the storage periphery is successfully tested. The collected data also gives first insights towards real-world availability times and open issues that still prevent permanent reliable operation.

Results from the operation of Hydrogen Hybrid Power Systems in large-scale are an inevitable step towards the expansion of the technology.
Topic/s:
B12-Hydrogen and Hybrid Power PLANTS
Effects of Communication Delays in Active Power Control of Hybrid Power Plants
Madheshwaran Lakshmipathy1, Kaushik Das1, Aeishwarya Baviskar2, Aivaras Celna2
1 Technical University of Denmark (DTU), Denmark
2 European Energy, Denmark
This paper investigates the impact of internal communication delays on active power dispatch in hybrid power plants (HPPs) comprising wind, solar, and battery energy storage systems. While having multiple renewable energy technologies and storage brings multiple benefits, it also introduces operational challenges subject to uncertainties and the coordination issues within multiple energy technologies, also particularly in multi-level control architecture plant-level to asset-level control. The geographical distribution of the technologies within an utility-scale HPP introduces communication latency due to several disturbances. This study investigates the impact of such communication delays within the hierarchical control structure, modelling them in the form of discrete and second-order delays. A detailed Power Factory model is developed under grid-following inverter configuration. The contributions of this work are threefold: (i) modelling a hierarchical active power dispatch strategy and evaluating representative edge case scenarios; (ii) overview and modelling of communication delays at sub-plant level control; and (iii) quantifying the impact of communication delays, including the stability margins and operational boundary limits of HPP controller. The results provide insights into the design of robust control architectures capable of maintaining stability and active power control in delay-prone communication environments.
Topic/s:
B1-Hybrid Power Plant Technologies and Design
A Novel Approach for Spatial Simulation of RES Integration Pursuant to the Regulatory Framework
MATTEO CONTU, Lidia La Maestra, Matteo Chiummarulo, Salvatore Picciau, Pierluigi Di Cicco, Federico Quaglia, Mauro Caprabianca, Lorenzo Del Rio
Terna S.p.A., Italy
The paper describes a proposed simulation-based methodology to spatially integrate plants powered by Renewable Energy Sources, based on the current regulatory framework regarding suitable areas. The achievement of European decarbonization targets requires a rapid and spatially coordinated deployment of Renewable Energy Sources, strongly conditioned by territorial constraints, authorization processes, and grid‑integration needs. In this context, recent European and national regulatory frameworks promote the identification of “suitable areas” and acceleration zones in order to streamline permitting procedures and reduce development bottlenecks. However, the large volume of connection requests submitted to Transmission System Operators often exceeds policy targets and it is not fully aligned with landscape characteristics and permitting features of the areas, posing significant challenges for efficient grid planning. This paper presents a GIS‑based simulation methodology aimed at quantifying the potential RES capacity eligible for authorization within a given territory by explicitly integrating spatial compatibility and authorization propensity. The proposed approach introduces a synthetic indicator – referred to as the Renewable Energy Density Index – obtained through the integration of four territorial dimensions: topography, environmental and landscape constraints, land use, and attractiveness for RES installations. Authorization likelihood is modelled through technology‑specific probability matrices and combined via a multiplicative overlay, enabling the computation of an aggregated Renewable Energy Spatial Capacity Allowable over user‑defined spatial domains. The methodology is applied to a case study, with a focus on photovoltaic technologies, demonstrating its capability to capture heterogeneous territorial conditions and to provide capacity estimates consistent with existing installations while identifying residual deployment potential. The results highlight the relevance of spatial resolution and authorization drivers in assessing renewable potential and confirm the suitability of the framework as a decision‑support tool for territorial energy planning and transmission system development under the current regulatory framework.
Topic/s:
A3-System Modelling and Simulation
THE ROLE OF BESS IN POWER SYSTEM EMERGENCY AND RESTORATION OF ISLANDED SYSTEMS
COSIMO PISANI, Francesco Del Pizzo, Cristiano Quaciari, Marco Galici, Giorgio Orlando, Guido Coletta, Matteo Contu
Terna S.p.A., Italy
Power systems are moving toward high shares of converter interfaced renewable generation, reducing synchronous inertia and short circuit power. Post blackout restoration strategies must therefore evolve to include inverter-based resources and Battery Energy Storage Systems (BESS) that can support post‑blackout restoration by sustaining small and stable islands. BESS can also act as controlled stabilizing loads and coordinate with conventional units that have successfully performed load rejection. This work addresses systems undergoing rapid coal phaseout, using Sardinia as a real-world reference. European regulation requires TSOs to define and maintain effective Restoration Plans; Terna’s approach is largely compliant, despite Italy’s geography and network characteristics make restoration planning inherently complex. Restoration paths must be updated frequently as the generation mix and network topology change. HVDC interconnections, already embedded in restoration plans, provide controllability but introduce specific constraints under low inertia and short circuit conditions. The proposed approach is validated through dedicated field tests by using measurements from generators and distribution system operators, preceded by simulation studies and ex-post-test reconstruction analysis. The paper presents criteria for the Sardinian restoration strategy, emphasizing coordinated use of existing HVDC interconnections together with emerging resources such as BESS and renewable energy-based generation to improve restoration robustness.
Topic/s:
A3-System Modelling and Simulation
Hardware-in-the-Loop Modelling and Validation of a Grid Forming Battery Energy Storage System
SILVERIO CASULLI, GIORGIO MARIA GIANNUZZI, GIOVANNI MASSA, ANDREA PORCU, SALVATORE TESSITORE, MATTEO CONTU, ROBERTO GNUDI
Terna S.p.A., Italy
The transition to decarbonized energy systems requires the adoption of new strategies and solutions to guarantee efficient power system management. Battery Energy Storage Systems (BESSs) represent a key component of the energy infrastructure, increasingly used to provide grid support, control and flexibility, making reliable real-time validation of their control systems increasingly relevant. This paper presents the development and Hardware-in-the-Loop (HIL) implementation of a real-time model of a utility-scale BESS. The objective is to provide a reliable replica platform to test the industrial control system under realistic operating conditions, including grid-connected and islanded operation. The plant model is developed in Matlab/Simulink using OPAL-RT ARTEMiS libraries, including step-up transformer, power conversion system, DC bus and battery banks. Each battery bank is represented by an equivalent circuit model parameterized from experimental data, providing an effective compromise between accuracy and real-time execution needs. The model is interfaced with the real BESS control system replica through analog and digital I/O, enabling closed-loop validation in a fixed-step real-time environment. Validation against real plant measurements shows very good agreement for battery voltage and good agreement for DC current. Islanded-operation tests further confirm correct load acceptance and stable stand-alone voltage and frequency regulation.
Topic/s:
A3-System Modelling and Simulation
The Limits of Simplicity: Rethinking EMS Design for Complex Hybrid Power Systems
Daniel Pombo
EPRI Europe, Ireland
Hybrid power systems combining generation, storage, and flexible demand behind a single point of interconnection are increasingly expected to operate as coordinated systems rather than collections of independent assets. In practice, many such systems still rely on rule-based energy management strategies that are robust, transparent, and easy to deploy. However, as asset portfolios grow in size and diversity—and as operational objectives extend beyond local reliability to include system interaction and service provision—the limits of purely rule-based control become apparent.

This paper examines the evolving role of energy management systems (EMS) in hybrid power systems, focusing on the architectural transition from rule-based to optimization-based control. Moving beyond a simple comparison of control techniques, the paper adopts a systems control perspective, reframing the discussion from “which approach performs better” to when and why different control paradigms become necessary. The central question is: where is the tipping point at which rule-based control breaks down, and what does “break down” mean in real hybrid systems?

Rather than positioning rule-based and optimization-based strategies as competing solutions, the paper frames them as complementary layers within a hierarchical control stack. In this architecture, rules provide safety, resilience, and fail-safe operation, while optimization enables coordinated decision-making across time, assets, and objectives. The paper focuses on EMS design principles, emphasizing the transition path from simple heuristic control to structured, scalable coordination frameworks.

Using representative hybrid system configurations that integrate renewable generation, battery storage, and flexible loads, the paper explores how increasing system complexity challenges traditional rule-based logic. Particular attention is given to stress conditions arising from combinations of market signals, operational envelopes, renewable availability, demand response events, state-of-charge and degradation considerations, and asset or communication outages. Across these scenarios, the analysis highlights where rule-based control begins to “break down” in practice—manifesting as inefficiencies, conflicting decisions, excessive conservatism, or loss of operational robustness—and identifies the conditions under which more advanced coordination becomes necessary.

The contribution is an architecture- and control-oriented perspective on EMS design for hybrid power systems. By shifting the narrative from tool comparison to control philosophy, the paper provides practical guidance for system designers and operators on how to structure layered control stacks that preserve the strengths of rule-based logic while enabling the benefits of optimization-based coordination as system complexity grows.
Topic/s:
B1-Hybrid Power Plant Technologies and Design
LOCAL PRICE AND INFRASTRUCTURE DEVELOPMENT IN THE SARDINIAN ELECTRICITY SYSTEM: THE STRATEGIC ROLE OF THE RES CAPACITY
Valerio Catalano, Camilla Maiolini, Fabio Genoese, Cecilia Pochini, Matteo Contu
Terna S.p.A., Italy
The ongoing transformation of the Italian electricity system is reshaping both the generation mix and the wholesale market architecture, with increasing relevance attributed to zonal price formation. In this context, Sardinia represents a paradigmatic case, being an island power system historically dependent on imports and characterized by strong sensitivity to local supply–demand conditions. The phase‑out of the Single National Price (PUN), the strengthening of interconnections with the mainland, and the development of the island transmission grid are expected to lead to a framework in which electricity prices for both producers and consumers will fully reflect local system conditions.

Within this evolving scenario, the level of Renewable Energy Source (RES) deployment emerges as a relevant driver of price dynamics. A significant expansion of solar and wind capacity, potentially exceeding local electricity consumption during specific hours, can reduce reliance on imported energy and residual thermoelectric generation, thereby lowering the Sardinian zonal price and mitigating exposure to national commodity volatility.

This paper presents the results of day‑ahead market simulations conducted for 2030 using a zonal representation of the Italian electricity system. Multiple scenarios are analyzed, sharing the same infrastructural configuration and market rules but differing exclusively in the level of RES integration on the island. The simulations assess the impact of alternative renewable development trajectories on zonal price formation, exchange flows with other market zones, and aggregate welfare indicators such as social welfare and the total value of transactions.

The results show that infrastructure development and market evolution, while necessary to enhance system integration and security, are not sufficient to ensure long‑term price competitiveness for Sardinia. Instead, the scale of local renewable capacity proves to be the decisive factor in determining the island’s economic positioning within the national electricity market. The paper finally discusses the implications for coordinated network–generation planning, highlighting infrastructure investments as enabling conditions for a sustainable, competitive, and resilient energy transition in the island power systems.
Topic/s:
A3-System Modelling and Simulation
Business Case and Profitability Analysis for a Synchronous Condenser Plant Hybridised with a Battery Energy Storage System
Marco Cioffi
Ansaldo Energia, Italy
In many regions, modern grids and power systems are dominated by power electronics with a reduced role for synchronous machines; they are therefore affected by increasing stability and reliability problems. In addition, large loads such as data centres and electrolyser plants are connected to the grid via power converters, and often they operate as non-programmable loads, harming grid stability.

Synchronous Condensers (SynConds) provide an effective and largely proven solution for enhancing grid robustness by supplying voltage regulation, reactive power support, short‑circuit power, and rotational inertia. They contribute to improved voltage quality, optimised power‑factor control, and enhanced system reliability.

Hybrid System for additional grid services

The ongoing evolution of national grid codes and electricity market frameworks is creating new opportunities for hybrid power systems, in which multiple generation technologies, such as inverter-based renewable (IBR) energy sources and conventional synchronous units, are integrated.

The presented project is based on a hybrid energy‑storage architecture that combines a SynCond with a Battery Energy Storage System (BESS), adopting a Grid-Forming Inverter. The synchronous condenser, coupled to a flywheel, enables the provision of stored rotational inertia, utilised to dampen frequency deviations and reinforce overall grid stability.

In parallel, the BESS is designed to store excess active power, for instance generated from renewables (RES), and discharge it when required. The combined deployment of these two technologies enhances the reliability and operational flexibility of power systems.

The two components, SynCond and BESS, are integrated and optimally managed by an in-house developed Smart Integrated Control tool (Plant Integrator). The hybrid system delivers significant advantages in the provision of grid‑support services, such as frequency and voltage control.

In combination, these technologies enhance system stability by increasing short‑circuit strength, improving frequency support, augmenting overall system inertia, reducing the rate of change of frequency (ROCOF), and enabling precise reactive‑power regulation. Furthermore, the hybrid configuration is capable of supplying black‑start functionality, further strengthening grid resilience.

Economic analysis and business case

An economic profitability analysis has been performed to evaluate the business case for the deployment of the hybrid system in the German grid scenario, where RES role is quite relevant, and a new inertia market is starting in 2026 (momentanreserve).

The combined SynCond and BESS optimise, in addition, the CAPEX by sharing part of the plant's electrical items. The hybrid system is able to catch larger revenue streams by providing the grid with a wider portfolio of services. This scenario reduces the business risk and increases the project's bankability.

Conclusion

The future of the Synchronous Condenser market looks promising, driven by the increasing integration of renewable energy sources and the need for grid stability. As countries worldwide continue to transition towards cleaner energy, the demand for Synchronous Condensers is expected to grow. These machines will play a crucial role in ensuring the reliability and stability of power grids, supporting the seamless integration of renewable energy.
Topic/s:
B10-Economic Evaluation of Hybrid Power PLANTS
Comparative Assessment of Short-Circuit Calculation Methods in Inverter-Dominated Power Systems
Laura Andrea Vega Restrepo1, 2, Jose Luis Rueda Torres2, Jeroen Popma1
1 Energy Solutions B.V., Netherlands
2 Technische Universiteit Delft, Netherlands
The increasing integration of inverter-based resources (IBRs) in power systems raises questions regarding the applicability of short-circuit calculation methods originally developed for synchronous generation. This work evaluates the limitations of IEC 60909 in systems with high photovoltaic penetration by comparing its results with dynamic RMS and EMT simulations, used as reference, and with two alternative approaches: the Complete Method and a Fault-Ride-Through-based method. The analysis is performed on the IEEE 14-bus system considering 25% and 50% IBR penetration levels and three fault types: three-phase, line-to-line, and single line-to-ground faults. The results show that IEC 60909 systematically overestimates short-circuit currents, with errors strongly dependent on the fault type, reaching up to 76% in single line-to-ground faults at 50% IBR penetration. The alternative methods significantly improve accuracy, but on different fault types. The FRT-based method provides the best performance for three-phase and line-to-line faults, while the Complete Method achieves higher accuracy in single line-to-ground faults. These findings suggest that no static method is uniformly suitable across all fault types, and that a complementary approach is required for short-circuit analysis in inverter-dominated systems.
Topic/s:
B8-Standards, Grid Codes and Grid Code Validation for Hybrid Power PLANTS
Operational Planning of Battery Energy Storage Systems Using Reinforcement Learning with a Predictive Model
Ryuichi Shibata, Shinichiro Minotsu, Gen Fukuda
Electric Power Development Co.,Ltd., Japan
Battery energy storage systems (BESS) in microgrids require dynamic control to handle uncertainty and variability in load, photovoltaic (PV), and wind generation. Assigning grid-support functions to the BESS further increases the control complexity. With large-scale renewable integration, electricity market price volatility has intensified, underscoring the need for operational strategies that adapt to real-time microgrid conditions while ensuring long-term profitability. Under such uncertainty, reinforcement learning (RL) can outperform conventional deterministic optimization. This study applies an RL-based controller to the optimal operation of a microgrid BESS.

We develop a Proximal Policy Optimization (PPO) controller that jointly optimizes local load supply and bidding in both the Real-Time Market and balancing markets. Compared with PPO without forecasts, augmenting the state with LightGBM-based PV generation forecasts increases total revenue.

We implement Python-based simulations of a microgrid comprising load and PV, where the BESS performs supply–demand balancing (same-time, same-quantity control) while participating in Real-Time Market and balancing markets. Market-based revenue is formulated as the reward under constraints such as state-of-charge (SOC) limits and power/energy capacity, and provided to PPO for policy learning. A PV forecasting model using Light GBM (Light Gradient Boosting Machine) leverages temperature and weather features; its forecasts are incorporated into the PPO state. We evaluate the effect of including PV forecasts versus PPO alone from a revenue perspective.

Prior applications of machine learning to BESS operation—especially in microgrids—are limited. Related EV studies often rely solely on real-time inputs; integrating forecasting with RL offers both novelty and practical value.

PPO‑based control is feasible for revenue‑maximizing operation of microgrid BESS. By incorporating PV output forecasts, cases with and without forecasts were compared, and the influence of adding PV predictive information on the RL‑based market‑participating microgrid control was confirmed.
Topic/s:
B6-Managing Variability and Uncertainty
A Stability and Performance Framework for Designing Energy Storage in Islanded Hydropower Systems
Viktor Döhlen1, 2, Danilo Laban3, 4
1 Department of Computer and Electrical Engineering – Mid Sweden University, Sweden
2 Sollefteåforsen AB, Sweden
3 Division for Electricity, Department of Electrical Engineering – Uppsala University, Sweden
4 Fortum Sverige AB, Sweden
This work presents a method for designing an energy storage system (ESS) operating in an islanded power system formed by a single synchronous machine. The method utilizes stability and performance criteria to define the island operation. The Nyquist stability criterion is used to ensure a stable response and a performance criterion is used to evaluate the island system's ability to contain the frequency within specified limits during island loading steps.

These criteria are derived using the same framework as Frequency Containment Reserve (FCR) criteria in the Nordic Synchronous Area. A closed-loop model of the island system, including a standard hydropower unit model and an ESS model, is used in MATLAB/Simulink. The models' response is optimized together with the defined criteria to obtain the size and control parameters for the ESS.

A case study with a Swedish hydropower unit with known power response dynamics operating in island mode is presented. Turbine test data is used to parametrize the linear hydropower model and an ESS is designed separately for FCR provision and island operation. The results of the case study show that 86 % more power from the storage system is needed for island operation than FCR provision according to the two defined sets of criteria. It is also shown that while island operation is the expected dimensioning mode for the ESS, the resulting EES size is very sensitive to the criteria and dynamics defined for the island system, with the load step size having the strongest influence on the ESS size.
Topic/s:
A1-Hybrid Power System Technologies and Design
Evaluation of Various Objective Functions for Optimal Reactive Power Flow Including Transformer Tap Changer Optimisation
Gerald Gebhardt, Bernd Engel
elenia Institute for High Voltage Technology and Power Systems, TU Braunschweig, Germany
Modern distribution grids with high penetration of renewable generation provide substantial flexibility through distributed reactive power sources and transformer tap changers. This high degree of freedom can be exploited for optimisation. However, choosing an objective function for optimisation is not trivial, e.~g. minimising grid losses may lead to overvoltages and minimising voltage deviations may lead to higher reactive power flows to neighbouring system operators. Thus, this paper deals with the design of an objective function for the centralised optimisation of distributed reactive power sources and transformer tap changers. Different objectives for characteristic network quantities are investigated for the optimisation and optimised in a combined manner and separately. The consequences of optimising conflicting target values are then analysed. For the optimisation, various grid usage cases of a 110 kV benchmark power grid from SimBench are examined. The investigated power grid is characterised by a high proportion of renewable energy plants. The optimisation is carried out in a data-driven, object-oriented manner using the interior point method with open source software. At the end of the paper, a meaningful optimisation function with combined weighted objectives is derived and the results are analysed.
Topic/s:
B3-System Modelling and Simulation
Rule-Based Versus Predictive Energy Management for Off-Grid Hybrid Power Systems: Case Studies in Four Regions
Venkata Siva Sathya Sairam Jagu, Michael Kleemann
KU Leuven, Belgium
Off-grid photovoltaic–battery–hydrogen systems are increasingly considered for remote and deployable installations. However, the benefit of a predictive energy management system (EMS) over a simpler rule-based EMS remains unexplored. This paper compares a rule-based EMS and a predictive EMS based on linear programming for a deployable system supplying a 1000-person military camp. A Python-based simulation framework models five years of operation at 15-minute resolution in four regions: Baltic States, Romania, Mali, and Congo. The predictive EMS reduces diesel fuel consumption and CO2 emissions by 5.54% in the Baltic States and by 9.01% in Romania, while only marginal improvements are observed in Mali and Congo. These results show that the benefit of predictive EMS depends strongly on climatic conditions.
Topic/s:
A11-Design of Energy Management Systems for Hybrid Power Systems
Experimental Investigation of a State-of-the-Art Electrolyser's Influence on Power System Stability
Timo Sauer, Marlene Pape, Bernd Engel
elenia Institute for High Voltage Technology and Power Systems, TU Braunschweig, Germany
Amid the ongoing expansion of renewable generation, cross-sector decarbonization remains essential, since certain industrial processes, e.g. steel production, cannot be directly electrified. In this context, green hydrogen and its derivatives emerge as a key technology pathway. Germany’s target to expand 10 GW of electrolysis capacity by 2030, however, introduces new challenges for power system stability. This paper examines the stability implications of a state-of-the-art anion-exchange‐membrane (AEM) electrolyser with grid‐following converter control.

First an overview of power system stability and quality, the AEM technology and the power electronics are presented. Afterwards measurement data using a high-precision grid analyser is shown. Based on this empirical dataset selected power system stability and power quality phenomena, the steady-state power parameters, the dynamic active power behaviour and harmonics are characterised. The experimental investigations show that the electrolyser has the potential to actively contribute to frequency stability as well as improve power quality. With regard to frequency-supporting control mechanisms, a distinction must be made concerning the time required for complete provision. However, the type of rectifier leads to current distortions with high total harmonic distortion values and a reactive power demand. The paper concludes by identifying critical integration challenges and proposing targeted strategies to improve secure and stable operation.
Topic/s:
B12-Hydrogen and Hybrid Power PLANTS
A Modular Energy Management System Architecture for Hybrid Power Plants: Design and Application to the Spanish Market
Jon Martinez-Rico, Amaia Santiago, Julen García, Ismael Ruiz de Argandoña
Tekniker – Basque Research and Technology Alliance, Spain
Hybridisation of renewable power plants with storage has become a central topic driven by the increasing midday price cannibalisation, declining investment costs of battery energy storage systems (BESSs), and growing technical curtailments resulting from higher renewable penetration. As a consequence, industry stakeholders now demand robust and validated operational solutions, including energy management systems (EMSs) for such power plants. These systems play a pivotal role in maximising revenues and extending the lifetime of critical assets such as BESSs. To address this need, this paper proposes a modular EMS architecture built upon industry-grade standards, enabling flexible adaptation to diverse hybrid plant configurations and evolving operational requirements from system operators or plant owners. The effectiveness of the proposed EMS is demonstrated through a case study of a PV–BESS hybrid power plant participating in the Spanish electricity markets.
Topic/s:
B10-Economic Evaluation of Hybrid Power PLANTS
Overview of Recent Microgrid Studies and Feedbacks : Evaluation of the Gain of Renewable Generation Forecast and Feedback on Frequency Control
Maxime VELAY1, Clement HUET2, Emeric BRUN1, Pierre HORSIN1
1 EDF R&D, France
2 EDF SEI, France
EDF SEI operates over 20 isolated micro grids, notably in French overseas territories and off the coast of Brittany. So far, those micro grids have mostly been powered by diesel engines; renewable energy sources and storage systems are progressively installed to reduce fuel consumption and emissions.

Some grids already integrate those resources and the ambition of the French regulator and of EDF SEI is to go towards 100% renewable penetration in the next decade.

EDF SEI and EDF’s R&D propose in this paper an overview of recent studies carried out to enhance the operation of the microgrids operated by EDF.

First, to operate those new systems, Energy or Power Management Systems (PMS computes setpoints based on power measurements and thus do not consider forecasts, whereas EMS computes setpoints based on current status and forecast of consumption and generation) are needed to control all the producers. Before investigating how to get good quality forecast, EDF SEI and EDF R&D evaluated the benefits that the forecast could bring to those micro grids in terms of renewable energy penetration and diesel savings.

To answer this question, the methodology employed consisted in comparing the results obtained from simulations of:

The current control laws of the PMS with different settings

The current control laws optimized based on perfect forecast

The day ahead optimisation of the use of the asset based on perfect forecast, including relevant constraints (margins, cost of genset start, renewable curtailment limitation)

The simulations were conducted on the case of Sein Island (Brittany) that has a peak load of 330 kW, and considering 400 kWc PV systems and 300kW / 277 kWh of storage system.

In conclusion, the maximum gain obtained in those simulations was 6% fuel reduction with perfect forecast and day ahead optimisation. Optimizing the PMS settings based on perfect forecast brought 3% saving in fuel consumption.

With those results, EDF SEI decided not to add forecast for the moment because it would not bring enough benefits, and even more when considering that forecasts are not perfect.

The second topic shared in this paper regards the periods when gensets and storage systems operate at the same time. In one of EDF SEI microgrid, the slow but large fluctuations of PV systems generation were not compensated by the storage system that was in grid forming mode with a droop frequency control. The expected behaviour of the storage system would have been to smoothen the fluctuations of gensets generation by following the PMS forecasts. It was not the case even when changing primary frequency control settings (offset, droop, dynamic of the control) which ended up damaging the gensets. From our understanding, the frequency variations and the dynamics of the PMS regulation did not work fast enough or the isochronous frequency regulation of the gensets was faster.

The solution implemented was to set the storage system in grid forming isochronous mode and to set the thermal plant in PQ mode with droop. This solution worked as expected.
Topic/s:
A2-Project Experience and Case Studies
High Inertia Flywheel for Supporting Energy Balance in Geographically Isolated Hybrid Electric Grids
Aleksandre Piranishvili1, Stephan Leschke1, Marco Merlo2, Matteo Spiller2, Tommaso Dieci2, William Resnati3, Mirco Pozzoli3
1 Piller Germany GmbH & Co. KG, Germany
2 Politecnico di Milano, Energy Department, Italy
3 TurnerMCS, Italy
Frequency control in islanded microgrids is expected to become increasingly critical as renewable energy sources (RES) increase

due to the decarbonisation target. The power electronic inverters that interface RES with the electrical grid inherently have low

inertia and limited short-circuit current, posing significant challenges to the operation of an isolated electric power system. To

address this emerging issue, new technologies must be evaluated and integrated into the electric power system. This study

investigates the impact of a high-inertia flywheel energy storage system (FESS) on the frequency control of the isolated

microgrid of Lipari Island in Italy. A newly deployed monitoring infrastructure provides high-resolution frequency

measurements at 160 ms intervals, enabling the development and validation of a detailed digital twin in DIgSILENT

PowerFactory, incorporating finely tuned synchronous generator dynamic models. To assess the impact that a FESS has on the

microgrid frequency control, the same contingency events are analysed under two distinct scenarios: 2026 and 2030, the latter

characterised by a higher penetration of RES. In the first scenario, the FESS enhances system performance relative to the

baseline case without it. The contribution of the FESS to the isolated microgrid frequency control reduces the nadir and the rate

of change of frequency (RoCoF) by 18% and 22%, respectively. In the second scenario, with a lower system inertia, the

contribution of the FESS drastically increases the reliability of the system since it is necessary to prevent frequency collapse.
Topic/s:
A3-System Modelling and Simulation
Inertia Contribution from a Grid-Connected Hybrid Power Plant: Technologies and Performance
Pim de Jong, Daniël Vree
Energy Solutions B.V., Netherlands
The increasing share of renewable energy sources is reducing the number of synchronous generators in the grid and therewith reducing system inertia. This results in faster frequency deviations, which could compromise grid stability. Transmission system operators (TSOs) are therefore implementing various measures to maintain the grid inertia.

This paper presents an overview of technical solutions for fast frequency support from grid-connected hybrid power plants, including inertia from synchronous condensers and synthetic inertia delivered by battery energy storage systems (BESS). The situation in The Netherlands and Germany is discussed regarding the development of a commercial market for synthetic inertia from grid-forming converters.

A case study is presented of a grid-connected hybrid power plant consisting of a 20 MW BESS integrated into a 90 MW wind farm connected to the 150 kV grid, where a third resource specifically for inertia support may be added. Two options are considered: a synchronous condenser with flywheel and an additional BESS equipped with synthetic inertia functionality. RMS simulations of the inertial response with the synchronous condenser are used to derive converter rating requirements for the additional BESS to deliver a comparable response.
Topic/s:
B11-Ancillary Services from Hybrid Power PLANTS
DAY-AHEAD BIDDING STRATEGIES FOR HYBRID POWER PLANTS USING PROBABILISTIC GENERATION FORECASTS
Alexandre MATHIEU, Rujie Zhu, Gregor Giebel
Denmark Technical University, Denmark
Hybrid Power Plants (HPPs) face increasing market price volatility ,and an appropriate design for their Energy Management System (EMS) could turn it into an advantage. Traditionally, control approaches are supported by deterministic forecasts and would benefit from a probabilistic approach to better manage market risks. This study investigates day-ahead bidding strategies to enhance HPP's profitability through EMS thanks to the development of probabilistic generation forecasts. The case study consists of a wind‑PV‑battery hybrid power plant located at Risø, Denmark. Day‑ahead (DA) and imbalance price forecasts are deterministic, while quantile-regression forecasts are generated for wind and PV production. The generated quantiles are then employed to simulate realistic Monte Carlo scenarios by preserving autocorrelation at lag 1. The EMS is modeled through the HyDesign-HiFiEMS tool with two approaches: (1) An EMS based on deterministic DA forecasts only. (2) An EMS with a stochastic optimization. Results show that the stochastic optimization approach leads to a 4.7% increase in profitability coming mainly from better spot market revenues and reduced battery degradation.
Topic/s:
B6-Managing Variability and Uncertainty
Increase the Value of Wind Power Plants Through the Hybridization with Solar Photovoltaic
Antonio Couto, Ana Estanqueiro
LNEG – Laboratório Nacional de Energia e Geologia, Portugal
The increasing penetration of variable renewable energy sources, such as wind and solar photovoltaic (PV), requires these technologies to actively support power system operation through participation in day-ahead and balancing markets, including the provision of ancillary services. In this context, hybrid power plants, where wind and solar PV share a common point of common coupling and are operated as a single unit, can provide technical and economic advantages compared to standalone plants. This work focuses on the “firm capacity” that can be offered in the Portuguese balancing markets using probabilistic power forecasts, considering the hybridisation of existing wind power plants with solar PV units. Results are compared with the standalone wind power plant and feature-based indicators are also explored to assess whether dynamic selection of forecast quantiles can increase the available capacity for balancing market. Two case studies in Portugal with different levels of wind and solar complementarity are considered. Results show that hybrid power plants significantly increase the amount of capacity available for market participation from 20.5% to 66.2% relative to standalone wind power plants. Thus, hybridisation enhances the ability of existing grid assets to provide ancillary services through participation in balancing markets.
Topic/s:
B7-Resource Assessment and Forecasting
Optimal Market‑Based Dispatch of Hydrogen Hybrid Power Plant Under Sequential Market Clearing and Price Uncertainty
Edoardo Beduglio1, 2, Anton Plietzsch2, Gloria Colmenares2, Christoph Nolden2, Mario Ragwitz1, 2
1 Chair of Integrated Energy Infrastructures, Brandenburg University of Technology, Germany
2 Fraunhofer Research Institution for Energy Infrastructures and Geotechnologies IEG, Germany
Hydrogen Hybrid Power Plants (HHPPs) play a key role in the energy transition, as their ability to transfer electricity over time facilitates the integration of renewable energy sources and supports grid stability and seasonal resource adequacy.

Ensuring their economic viability is a prerequisite for large-scale deployment and requires operational strategies that are both optimal and market-consistent. This study proposes a deterministic multi-step Mixed-Integer Linear Programming (MILP) framework that explicitly reflects the sequential structure of European electricity markets, including wholesale markets (day-ahead and intraday) and ancillary services such as Frequency Containment Reserve (FCR) and automatic Frequency Restoration Reserve (aFRR).

Unlike deterministic simultaneous co-optimization approaches, the proposed model emulates real short-term operation by solving consecutive market stages based on ex-ante price forecasts, thereby capturing the temporal ordering and commitment constraints inherent to actual market participation.

The framework derives realistic optimal dispatching and bidding strategies that maximize revenues across multiple markets while enhancing system flexibility and enabling effective peak load mitigation.

The results highlight the importance of explicitly modelling market sequencing, as sequential clearing induces systematic deviations from pre-clearing schedules, requiring dynamic flexibility reallocation, and identifies ancillary services markets as the primary revenue driver.
Topic/s:
B10-Economic Evaluation of Hybrid Power PLANTS
Resilient Operational Concept Including Grid-Forming Properties and Study-Based Verification for Offgrids and Weak Grids
Carsten Heising1, Roman Bartelt1, Daniel Meyer1, Cornelius Heck2
1 Avasition GmbH, Germany
2 50Hertz transmission GmbH, Germany
Operational concepts for offgrids and weak grids are a major challenge in general but especially in case of converter domination. The energy transition world-wide results in different offgrids, microgrids and weak grid situations which share the characteristic and related challenges of converter domination. Beside other aspects, the lack of energy-buffering inertia as well as instantaneous stability and interactions between controlled converters can be identified as key challenges.

In order to design a resilient operational concept, the fundamental design rule of power-system backbones have to be taken into account: explicit communication is only allowed to optimize the loadflow – in case of any disturbance in communication, the power system has to operate in a stable manner. This golden rule is even more relevant nowadays due to extended risk of cyber security issues. Today, ever so often communication is defined es central aspect for a resilient smart grid or any other grid configuration which includes a high unnecessary risk due to possible cyber attacks.

Within this paper, a resilient operational concept is presented which is compatible with grid-forming properties and fulfils the introduced control rule of power-system backbone design. A further novelty is the fact that also dynamic infeed-sharing can be parametrized easily which is essential for any weak-configuration in hybrid constellations with e.g. BESS. The performance of the operational principal is verified in different challenging scenarios including different converter dimensioning in detailed EMT-based grid calculations. The performed study will analyse typical fault and stability scenarios and will also include a detailed protection analysis specifically for the converter-dominated grid. The scenarios will include the emulation of communication failures and cyber-security intrusions. This is crucial for any new operational-concept proposal. Furthermore, the implementation is verified by HIL analysis and comparison of a laboratory measurement of a subset of the system analysis. The final paper will include all utilized framework, digital twin and laboratory components enabling the detailed analysis of the introduced concepts.
Topic/s:
A5-Intelligent Control and Grid Stabilization
Automated Compliance Testing and Model Validation Consistent for Grid Planning, Project Execution and System Operation
Carsten Heising1, Roman Bartelt1, Daniel Meyer1, Jannis Brodmann2, Cornelius Heck2
1 Avasition GmbH, Germany
2 50Hertz Transmission GmbH, Germany
The subtransient and fast transient system characteristics of conventional power systems based on synchronous-generator feed in are dominated by the physical electrical equations of rotating machines and comparable slow exciter control and technology control loops. In contrast, the introduced fast system characteristics of modern grids including various converter-based infeed and load assets are dominated by algorithms which aim to satisfy grid-code requirements in specific countries. To achieve an adequate security of supply, an enormous increase in compliance testing is a must. To master this challenge with the necessary quality with acceptable costs and resource requirements, an automated compliance testing is a must.

The novelties cover two dimensions: On the one hand side, automated assessment is extended for converter assessments covering all adequate requirements to determine trustful results. On the other hand, the automated assessment is extended to transient and subtransient assessments by utilizing dynamic envelope curves based on the actual grid states – e.g. positive and negative sequence fundamental voltage as well es frequency. Furthermore, live-model estimation in the scope of converter properties like e.g. transient behaviour as well as voltage-forcing properties is a new topic.

Within this paper, an approach to achieve consistent automated compliance testing and model validation for grid planning, project execution and system operation is presented and backed by measurement, HIL and simulation assessments of commercial projects. The assessment algorithms are formulated in a neutral high-level language in order to be able to use the algorithms on different operating systems and in FPGA utilizing code generation and sophisticated interpreters. Based on this neutral formulation, assessment algorithms can be improved in standard commercial grid-calculation tools like e.g. PSCAD, PowerFactory, ATP, VIAvento and deployed to field-measurement devices in a consistent way. Furthermore, the algorithm can be integrated in modern system-operation platforms ever so often built in Kubernetes clusters, e.g. for ex-post analysis or dynamic security assessment. Additionally, results of the model estimation of real assets are given.

A special focus is on the realization of an adequate converter assessment covering not only the steady-state behaviour but also subtransient and transient responses as well as harmonic emissions. Results will be showcased utilizing a weak grid-connection scenario with generic data due to restrictions on vendor IP in the real setup. Field measurement results from commercial projects are given and compared with simulation results.
Topic/s:
B5-Metering and Park Control Concepts
Optimization of Analysis Quality and Effort Through Utilization of Tool-Neutral Data Handling, Process Automation and Large-Scale EMT System Analysis
Carsten Heising1, Roman Bartelt1, Martin Richter1, Cornelius Heck2
1 Avasition GmbH, Germany
2 50Hertz Transmission GmbH, Germany
The energy transition results in converter-dominated grids all over the world. Especially in off-grids and week grid-connections, the properties of controlled converters are dominating, leading to new challenges in system design, technical quality management of components and grid integration. To put this in practice, already minor faults in planning or control-algorithm development can result in accelerated aging or damage of components and relevant project delays. To enable the required detailed analysis, ever so often various grid-calculation tools and HIL systems are utilized, resulting in a high effort in resources and costs which is additionally a project risk due to the shortage of experienced experts in controlled power-electronic converters in power systems. Furthermore, there is a need for large-scale EMT-grid calculations to minimize the risk of inadequate behaviour within a large off-grid converter grid or of the interaction between the connected park and the weak grid.

Within this contribution, a new approach towards asset-data management adequate for relevant deep technical aspects of controlled power-electronic converters and an automated process approach for generating models for selected commercial tools will be presented and showcased with an off-grid scenario with 8 controlled converters. The setup will include the offline-simulation tools PSCAD, PowerFactory, VIAvento, Netomac as well as an automated FPGA-based HIL setup with microsecond resolution. The potential EMT grid-calculation performance of more than 100 controlled converters will be showcased with the commercial tool VIAvento. Also, other grid-calculation methods like RMS and harmonic calculation will be included. The results of the different commercial grid-calculation tools and simulations methods will be compared based on a selection of typical studies for grid assessment and grid access, respectively. Lessons learned on technical requirements will be included in the final paper – this includes learnings from using the original control in DLL and shared object from working on different operation systems like Windows, Linux and IOS, relevant e.g. in grid planning, project execution and dynamic security assessments. All these technical novelties aim to create a disruptive process in terms of utilized expert resources.

This introduced and showcased process approach allows for more simulation cases with more technical relevant details in the scope of converter applications. Based on this, the analysis quality as well as the resource utilization can be optimized, leading to a minimization of commercial and time-line project risks.
Topic/s:
B3-System Modelling and Simulation
Multi-objective Sizing and Control Strategies of Hybrid Energy Storage Systems for Wind Turbine Applications
Gulasalkhon Musinova, Wilfried Hofmann
TU Dresden, Germany
Despite the rapid growth of wind energy, its inherent variability and uncertainty introduce significant challenges for power system operation. Power fluctuations, reduced power quality, and difficulties in meeting grid code requirements become more pronounced at higher penetration levels. Energy storage systems (ESS) have therefore gained increasing attention as an effective solution, enabling power smoothing, improving system stability, and supporting grid services such as frequency regulation and low-voltage ride-through (LVRT).

In this context, this work focuses on the selection of hybrid energy storage system (HESS) technology, its integration architecture, and the development of a unified framework that simultaneously considers power smoothing, LVRT, and frequency support requirements. A modified mean-value dispatch strategy with a predefined regulation band is introduced to reduce power fluctuations while minimizing storage capacity. In addition, a hierarchical control framework is developed to enable coordinated power allocation between storage units while incorporating state-of-charge (SOC) constraints.

The study utilizes one hour of wind data to evaluate power smoothing performance. Dispatched power references are generated using mean-value, min–max, and ramp-rate-limited methods for comparison. The proposed band-limited mean-value strategy aims to reduce ESS size while satisfying grid code requirements. The HESS sizing is carried out using a multi-objective approach that considers power smoothing, LVRT conditions, and frequency support requirements.

A coordinated control framework is implemented for different operating modes, including normal operation, voltage disturbances, and frequency events. During normal operation, power is allocated between storage units using low-pass and high-pass filters. During voltage disturbances, the HESS absorbs excess energy at the DC link, with the supercapacitor providing fast dynamic response and the battery contributing when required. During frequency events, the supercapacitor provides inertial response, while the battery supplies sustained frequency support, considering SOC constraints.

The results demonstrate that the proposed framework effectively determines the required HESS capacity for a 7 MW PMSG-based wind turbine system. For power smoothing under a ±5% regulation band, a HESS capacity of 154 kWh and a rated power of 2.7 MW are obtained, operating within a 0.6 SOC window.

During LVRT conditions, the HESS maintains the DC-link voltage at 1200 V while the generator continues operating at maximum power point tracking (MPPT). The required energy absorption is approximately 1.47 kWh over a 1.5 s recovery period, significantly reducing the dependence on braking choppers.

Furthermore, the HESS successfully provides inertial response and frequency support without affecting MPPT operation. To emulate a virtual inertia of 3 s under the German worst-case scenario (RoCoF = −2 Hz/s, Δf = 1 Hz), a peak inertial power of 1.68 MW and an energy of 0.233 kWh are required. The corresponding frequency-support power is 2.8 MW, with energy requirements of 7.78 kWh and 23.33 kWh for 10 s and 30 s durations, respectively.
Topic/s:
B4-Storage Design and Sizing
CONCEPTUAL ANALYSIS AND FEASIBILITY OF a HYDRAULICALLY-COUPLED PUMPED SOLAR HYBRID HYDROPOWER SYSTEM FOR a REMOTE COMMUNITY IN CANADA
Andrew Swingler1, George Colgate2
1 University of Prince Edward Island, Canada
2 Xeni Gwet'in First Nation, Canada
This paper investigates the feasibility of a hydraulically coupled pumped solar hydro system as a supplemental energy resource for a potential remote community hydropower installation in Canada. The proposed architecture converts photovoltaic (PV) electricity directly into hydraulic energy through solar-powered pumping, thereby avoiding the need for conventional electrical energy storage and power conversion systems.

The system is designed with an emphasis on simplicity, modularity, and robustness to suit the constraints of the isolated community. An initial modular pumping concept is developed and its hydraulic performance evaluated based on representative component characteristics. A system-level energy modelling approach is then implemented to assess the required solar capacity and reservoir storage as a function of increasing community load.

Results indicate that the proposed approach can effectively augment seasonal water inflows and enable significant load growth while maintaining a fully renewable energy supply. The analysis highlights key design trade-offs, including PV oversizing and pump technology selection, and identifies areas requiring further investigation.
Topic/s:
A1-Hybrid Power System Technologies and Design
The Opportunity for Electric Cooking to Open New Markets for Hybrid Systems
Peter Lilienthal
EarthSpark International, United States
Two billion people still cook with unhealthy and environmentally destructive biomass. One third of them currently have no access to electricity at all and the other two thirds have unreliable access. Cooking is by far the largest use of energy in these households. Until recently hybrid systems using solar photovoltaics and batteries were too expensive to compete with biomass, but this is no longer true. This presentation discusses market entry strategies with analytical results. It will also discuss the complexities associated with the subsidies available from carbon credits to accelerate this application.

The market for hybrid-based cooking solutions falls into four categories:

Institutional users, such as schools and hospitals: These make an attractive entry market because of the scale and timing of their cooking requirements. They require larger systems and perform most of their cooking during the daytime.

Off-grid households in dense enough communities to support a mini-grid: The presentation will show how the addition of cooking helps the financial sustainability of mini-grids in Haiti. Although those systems manage the resource variability just with load management, analysis shows potential cost savings with limited use of a backup generator.

Dispersed off-grid households: In some ways these are just much larger solar home systems. The important difference is in their required approach to storage.

Grid-connected households: This could be the largest market, given how much charcoal is still consumed in urban areas. The only essential requirement for this market is a storage system that meets the unique requirements of cooking applications. Scaling up the manufacturing and distribution of these storage systems would have a major spin-off benefit for applications that hybridized them with solar.

The unique characteristics and design requirements of each of these market segments will be discussed with analytical results, along with the synergy between them. Rethinking the role and design of storage systems and load management is the key to unlocking these potentially large markets for hybrid systems.
Topic/s:
A12-Economic Evaluation of Hybrid Power Systems
Modelling and Simulating a Microgrid System at Åland University's Energy Lab Using MATLAB Simulink and Simscape
Kottage Don Chamila Nanda Jayawardana, Florian Haug
Åland University of Applied Sciences, Finland
Hybrid microgrids with high penetration of inverter-based renewable energy require reliable modelling and control to ensure stable and secure operation, particularly during transitions between grid-connected and islanded modes. This paper presents the modelling and simulation of the hybrid microgrid at the Åland University of Applied Sciences Energy Lab using MATLAB Simulink and Simscape. The system includes a 60 kWp photovoltaic plant, a 10.2 kWh battery energy storage system, two 100 kW diesel generators, and a range of controllable loads. A detailed component-level model was developed to represent the electrical and dynamic behaviour of generation, storage, and load subsystems. A supervisory control strategy was implemented to enable power balancing, load management, and coordinated source synchronisation. Simulation studies were conducted for grid-connected operation, planned islanding, black start, and grid resynchronisation. The results demonstrate stable voltage and frequency regulation and effective coordination between energy sources during operating mode transitions. The developed simulation model provides a platform for analysing hybrid microgrid performance and supports further research, control development, and education for resilient and sustainable energy systems..
Topic/s:
A3-System Modelling and Simulation
State-Machine-Based Transition Control and Scenario Verification for Industrial Hybrid Microgrids
Francesca Perino4, Sid Attia2, Miguel Alonso1, Rajarshi Dutta3, Sai Sasank Kota3
1 The MathWorks Spain, Spain
2 MathWorks Germany, Germany
3 MathWorks India, India
4 Mathworks, Italy
This paper describes a workflow for implementing and verifying transition control in an industrial hybrid microgrid (diesel–PV–BESS) with two microgrids coupled by a normally-open tie switch and interfaced to upstream networks through two primary substations. Each substation hosts a microgrid controller and a grid-forming BESS at the PCC; a supervisory layer issues operating commands and collects measurements for verification. The workflow is structured using the IEC TS 62898 series for microgrid project guidance and operation/control context and uses IEEE 2030.7/2030.8 as a controller-function taxonomy and a verification/test structure.

The workflow makes transition functions explicit as state-machine sequences, including breaker actions and setpoint/mode sequencing, and verifies them through a fixed scenario-based test suite with metric-based evaluation. It comprises requirements capture with standards mapping and voltage/frequency deviation envelopes used as pass/fail gates, controller decomposition into dispatch and transition functions, state-machine design for transition sequencing, reference generation for BESS setpoints (P/Q/V/f) and mode control, scenario execution, and verification using voltage/frequency envelopes and power-quality indicators with event-oriented logging aligned with IEEE 2030.8 monitoring categories. Modular, parameterizable DER unit models are used for PV, BESS, and diesel; each unit encapsulates plant dynamics together with its low-level control (and interface where applicable), allowing ratings and operating constraints to be changed without restructuring the supervisory transition logic.

Five scenarios are executed to exercise transition functions: planned islanding with ramp-down of grid power exchange prior to breaker opening, resynchronization using voltage/frequency/phase alignment prior to reconnection, black start of each microgrid with staged energization and load pick-up, and a disturbance scenario with three-phase-to-ground fault emulation followed by operational reconfiguration (islanding and tie-switch closure). Outputs include pass/fail evaluation against configured voltage/frequency envelopes, summary statistics of max/min deviations across cases, and power-quality checks including THD at PCC and load together with load-voltage deviation limits, aggregated into a verification summary package (metrics, event logs, key waveforms, and test results). Techno-economic sizing and detailed protection coordination are treated as separate workflows and are not within scope.
Topic/s:
A2-Project Experience and Case Studies
Real-Time MPC-Based Energy Management of a PV-Integrated Hybrid Storage System with Redox Flow Battery and Supercapacitor
Saman Korjani1, Lorenzo Colturato1, 2, Edoardo Gino Macchi1
1 Fondazione Bruno Kessler, Centre for Sustainable Energy, Via Sommarive 18, 38123 Trento, Italy
2 Università degli Studi di Trento, Department of Industrial Engineering, Via Sommarive 9, 38123 Trento, Italy
This paper presents a real-time model predictive control (MPC) framework for a grid-connected PV system integrated with a hybrid energy storage system (HESS) composed of a redox flow battery (RFB) and a supercapacitor (SC). The control architecture consists of two layers: a genetic algorithm (GA) performs a six-hour rolling-horizon optimization at hourly resolution to schedule the RFB for electricity-cost minimization, while a minute-level supervisory layer executes the schedule in real time and coordinates the SC to compensate fast power mismatches, ramp-rate violations and short-timescale deviations. The framework accounts for grid interconnection limits and storage constraints, and its modular design enables adaptation to other storage technologies, alternative control objectives and various systems.The method is evaluated using field data from the Technology Center for Energy at Landshut University (TZE) and compared with a stand-alone RFB and a rule-based benchmark under practical-forecast and perfect-foresight conditions. Results show that SC support reduces battery-limited tracking periods from about 60% to 18%, as the SC absorbs fast mismatches and improves RFB tracking real-time feasibility. In addition, the GA-based controller increases arbitrage profit by about 10% compared to the rule-based benchmark. Overall, coordinated RFB–SC operation enhances both economic performance and constraint-compliant real-time energy management.
Topic/s:
B14-Others
Techno-Economic Assessment of the Integration of Vanadium Redox Flow Battery in an Islanded Diesel-RES Hybrid Power Plant
Lorenzo Colturato1, 2, Saman Korjani1, Giacomo Moretti2, Edoardo Gino Macchi1
1 Fondazione Bruno Kessler, Centre for Sustainable Energy, Italy
2 Università degli Studi di Trento, Department of Industrial Engineering, Italy
Islanded microgrids with high penetration of renewable energy sources (RES) often rely on diesel generators to maintain power balance, leading to significant fuel consumption and renewable energy curtailment. To address this challenge, this study evaluates the integration of a vanadium redox flow battery (VRFB) as a long-duration energy storage (LDES) solution to support the decarbonization of islanded hybrid power systems (HPS). The analysis is based on one year of minute-resolution operational data from the Graciólica plant on Graciosa Island (Azores), combining wind, solar photovoltaic (PV), and diesel generation. A simulation framework implemented in OpenModelica was developed to assess system performance by combining a physics-based system-level VRFB model with a rule-based energy management system (EMS) that coordinates battery and diesel operation under practical operational constraints. Multiple VRFB configurations (0.5-4 MW, 4-16 hours) were evaluated through a techno-economic analysis considering battery costs, fuel prices, and monetized CO2 emissions. Results showed that increasing VRFB capacity substantially reduces diesel consumption and renewable energy curtailment, although marginal benefits diminish with longer storage durations. Under current cost assumptions, mid-sized configurations provided the most favorable techno-economic trade-off, achieving significant diesel reduction with payback periods approaching five years.
Topic/s:
A18-Others
Dynamic Cable Rating for Wind-PV Hybridization of Existing Wind Farms
Katarina Obradović1, Kaushik Das1, Pierre-Elouan Réthoré1, Stefan Røpke1, Moataz El Sied2, Nouha Dkhili2
1 Technical University of Denmark, Denmark
2 TotalEnergies, France
New grid connections are becoming harder to secure. At the same time, electricity demand rises, putting pressure on the precious metal extraction and supply. This increases the importance of better utilizing allocated grid capacity and existing in-plant electrical infrastructure. One practical solution is to hybridize operating wind farms (WFs) with solar photovoltaic (PV) systems by connecting directly to the existing internal medium-voltage (MV) cable network, thereby avoiding the need for new MV cables and a new grid connection.

This paper presents a methodology for estimating the amount of PV capacity that can be integrated into an existing WF without reinforcing the internal cable network. The approach is based on three main principles: the temporal complementarity between wind and solar generation, operational curtailment strategies, and the possibility of allowing short-term cable overloading by accounting for cable thermal inertia.

The framework is demonstrated on a 22.5 MW onshore WF in Denmark with a radial collection network. Results show that, under conservative assumptions, approximately 25% of installed capacity can be added as a PV system while respecting needed cable constraints. Allowing limited cyclic overloading can increase the admissible PV capacity by up to a factor of two for certain cables, while overloading events remain rare and short. Across all evaluated cases, hybridization improves the grid utilization factor by up to 31%.

Overall, the results show that coordinated wind–solar operation and flexible cable utilization can support more efficient use of existing infrastructure and facilitate the integration of renewable energy in grid-congested areas.
Topic/s:
B1-Hybrid Power Plant Technologies and Design
The Wait Is Coming to an End: Grid Code Compliance for BESS in Hybrid Power Plants Under the Revised European Network Codes
Bernhard Schowe-von der Brelie1, Syed Mansoor Ali2
1 FGH Research Association (FGH e.V.), Germany
2 FGH GmbH, Germany
Hybrid Power Plants (HPP), combining renewable generation units and new consumption patterns with Battery Energy Storage Systems (BESS), are becoming a cornerstone of the European power system transformation. Baring a broad and highly dynamic flexibility, BESS play a critical role in providing strongly needed system services to enable higher shares of inverter-based resources both on generation and on consumption side while supporting system stability. Reflecting this evolving role, the revisions of the European Network Codes Requirements for Generators (RfG) and Demand Connection Code (DCC) have been intended to explicitly address hybrid assets and energy storage systems as system-relevant grid users. This is an important extension as the initial Network Codes as of 2016 have not addressed storage systems at all, except for pump hydro. The revisions had been elaborated based on a European wide stakeholder involvement conducted by ACER already back in 2022/2023. A final draft had been handed over to the European Commission to conclude the legislative process, which is, however, pending since then. Recently, the Commission, has announced that the codes shall be published in 2026, hence, ending a long period of waiting for an entire industry.

This contribution discusses the anticipated technical requirements for BESS within Hybrid Power Plants as they emerge from the revised RfG and DCC drafts. Key focus areas include requirements related to frequency and voltage support, fault ride-through capability, dynamic reactive power provision, active power control, as well as observability, controllability, and communication at both plant level and point of connection.

A particular emphasis is placed on the dual nature of BESS, which can operate as both generation and demand, and the resulting implications for the applicability, interaction, and alignment of RfG and DCC provisions. The paper highlights those areas where the revisions aim at greater harmonisation of technical requirements across Europe, while also identifying aspects that are likely to remain subject to national implementation and interpretation.

In addition, the contribution addresses conformity assessment and compliance demonstration obligations under the European Network Codes. It outlines the expected requirements to provide technical documentation, simulation models, and test evidence to the responsible system operator, and discusses open questions regarding the scope of conformity assessment for hybrid configurations, including the allocation of compliance responsibilities between individual components and the hybrid plant as a whole.

Despite the technical clarity achieved in the draft Network Codes, the continued delay in their formal adoption and publication has created a prolonged regulatory limbo. For manufacturers, project developers, and system operators, this situation complicates grid connection agreements, conformity assessment strategies, and investment decisions, as projects must already be designed against requirements that are known in substance but not yet legally binding. This contribution therefore critically examines how the industry is navigating this transitional phase and which technical and procedural approaches may help bridge the gap between long-available drafts and their awaited implementation. A rough comparison with already existing technical provisions in national grid codes is demonstrated.
Topic/s:
B8-Standards, Grid Codes and Grid Code Validation for Hybrid Power PLANTS
Role of Grid Strength in Maintaining Stability of Weak Island Power Systems
Vahan Gevorgian
National Laboratory of the Rockies (NLR), United States
The operation of inverter-based resources (IBRs) in regions with low system strength and high grid impedance has been identified as a primary cause of various power system instabilities. These instabilities often manifest as oscillations and dynamic interactions that, if not properly mitigated, can jeopardize the reliable operation of the grid. Weak grid conditions amplify such issues, particularly when multiple IBRs operate in close proximity and are interconnected within low-strength power networks.

Traditionally, synchronous generation-based resources inherently provided grid strength through their physical electromechanical characteristics, without the need for specialized control schemes. In contrast, IBRs lack this natural contribution to system strength, making the role of control strategies and system support technologies much more critical. Grid strength profoundly influences the overall stability of islanded or inland power systems with high IBR penetration, particularly affecting voltage regulation, fault response, and transient stability.

Technology selection therefore plays a pivotal role in achieving the desired level of grid strength in a secure and reliable manner. This paper presents research conducted at the National Laboratory of the Rockies (formerly NREL) on stability-oriented modeling and testing of hybrid systems designed to enhance the dynamic performance of islanded grids. The work includes case studies evaluating the optimal balance between grid-following and grid-forming inverters, as well as the application of stability-enhancing technologies such as hybrid plants, synchronous condensers, and battery energy storage systems.
Topic/s:
A3-System Modelling and Simulation
Framework for Harmonic Compliance Assessment of Complex Hybrid Power Plants Integrating PV, Wind and Power-to-X
Björn Andresen, Arman Fathollahi, Niclas Lawrence, Jens Christian Gammeljord Nielsen
Department of Electrical and Computer Engineering, Aarhus University, Aarhus, Denmark, Denmark
The green transition is driving a rapid expansion of renewable energy sources (RESs) and electrified energy conversion pathways, requiring power grids to accommodate more power electronic-interfaced facilities and new forms of flexible demand. In this context, complex hybrid power plants (CHPPs) integrating RESs such as PV and wind, together with large-scale energy storage such as Power-to-X systems, are increasingly connected to the grid as power converter-dominated facilities. Under these conditions, harmonic emission, background distortion and grid-impedance interaction become central elements in grid-connection assessment and power-quality compliance. Harmonic compliance studies for CHPPs are often carried out through workflows that depend on case-specific modeling choices, manual configuration steps and undocumented assumptions regarding harmonic sources, aggregation and study setup. This can lead to limited transparency and weak reproducibility when models are transferred between stakeholders or when results are reviewed as part of compliance documentation. This paper develops a framework that structures the harmonic compliance assessment process from requirement capture to model configuration and acceptance testing in DIgSILENT PowerFactory. The framework is organized into two parts. First, a modeling guideline defines a systematic procedure for representing and parameterizing CHPP subsystems, including explicit documentation of input data, assumptions and plant-level aggregation choices, as well as consistent handling of harmonic source definitions and background harmonics. Second, a standardized test specification defines repeatable study cases that correspond to typical compliance needs, including load-flow consistency checks, harmonic load-flow analysis, background harmonic evaluation, frequency sweep studies and grid-impedance variation assessment. The verification logic is aligned with a structured development approach inspired by the V-model, where requirements are mapped to configuration activities and associated acceptance tests to support traceable validation of both the model and the study procedure. The work is validated through an industrially hybrid power plant including Power-to-Ammonia, Wind power - and PV production in Denmark. Using the available facility specifications, a reference plant model is recreated by following the requirements-driven framework and the defined test suite is executed on both the original and recreated models under identical study conditions. The comparison indicates close agreement across the main harmonic- and impedance-related study outputs, including consistent harmonic load-flow indicators and aligned frequency-domain impedance responses across the considered operating conditions and grid-impedance variations which demonstrates that the proposed framework supports systematic model recreation and consistent compliance-relevant results.
Topic/s:
B8-Standards, Grid Codes and Grid Code Validation for Hybrid Power PLANTS
The New Economics of Reliable, Secure 24/7 Renewable Power: How Storage Is Redefining the Cost of Firm Solar and Wind
Saied Dardour, Deborah Ayres, Lourdes Zamora
IRENA - International Renewable Energy Agency, Germany
As global power systems transition towards higher shares of variable renewable energy, ensuring a reliable, continuous electricity supply has become both a systemic integration challenge and an increasingly viable plant-level design objective. This paper introduces the firm levelised cost of electricity (F-LCOE) framework to assess the economics of hybrid power plants — combining utility-scale solar PV or onshore wind with co-located battery energy storage — as a transparent, replicable benchmark for comparing firm renewable power with conventional dispatchable generation.

Using a linear optimisation model applied to IRENA's global database of hundreds of utility-scale projects, we determine the least-cost combination of generation overbuild and storage capacity required to deliver a constant power output across reliability targets ranging from 90% to 99%. Our findings show that firm renewable costs have fallen sharply — from above USD 100 per MWh in 2020 to USD 54-82 per MWh at high-quality locations in 2025 — and that in leading markets such as China, hybrid systems already deliver firm electricity well below the cost of new coal and gas-fired generation across a wide range of reliability targets. Further cost reductions of 30-40% are projected by 2030-2035 as solar, wind, and battery storage costs continue to decline.

A sensitivity analysis reveals that resource quality and temporal generation patterns — particularly the depth and duration of prolonged low-generation events — are the primary determinants of firming costs, outweighing the influence of capital expenditure and reliability targets. Short-term variability plays a secondary role; it is the persistence of supply shortfalls, not their frequency, that drives storage and overbuild requirements. Technological diversification — combining solar PV and wind within a hybrid configuration — significantly reduces firming costs relative to single-technology configurations by exploiting the natural complementarity between the two generation profiles and reducing the need for large storage volumes.

The paper concludes that hybrid power plants represent an increasingly cost-competitive and commercially mature solution for firm, dispatchable renewable power in diverse geographical and market contexts — and that, at a time when fossil fuel dependence is once again exposing economies to acute price and supply risks, the energy security case for firm renewables is as compelling as the economic one.
Topic/s:
B10-Economic Evaluation of Hybrid Power PLANTS
Analysis of Earthing Systems for Personnel Safety and Protection Sensitivity in Microgrid Distribution Network
Elie Salhab, Maxime Velay
EDF R&D, France
EDF SEI operates over 20 isolated micro grids, notably in French overseas territories and off the coast of Brittany. So far, those micro grids have mostly been powered by diesel engines ; renewable energy sources and storage systems are progressively installed to reduce fuel consumption and emissions.

Due to the diversity of installations, there is a growing need to harmonize neutral earthing systems in medium-voltage (MV) distribution networks in order to simplify equipment procurement and ensure consistent protection practices, particularly for inland municipalities in French Guiana.

Recently, abnormal overvoltages were observed in the MV network of Saint Martin. A dedicated R&D study identified the neutral earthing scheme as the root cause of excessive potential rise. As a mitigation measure, a modification of the neutral earthing system was implemented at the end of 2025, pending a long-term solution. This event motivated a more general study aimed at systematically assessing the technical advantages and limitations of various neutral earthing regimes applied to isolated microgrids, with the objective of identifying a technically optimal solution adaptable to the wide range of microgrids operated by EDF SEI. The study evaluates different neutral earthing configurations based on three main criteria:

Personnel safety assessed through touch voltage,

Equipment protection assessed through healthy phase overvoltage,

Residual current and voltage protections sensitivity.

A dedicated calculation code was developed in MATLAB to compute earth-fault currents and touch voltages under various operating conditions. The results were validated against detailed simulations performed using EMTP‑RV. This calculation tool enables efficient evaluation of personnel safety and protection performance for a wide range of configurations, including generator power, neutral earthing impedance, MV cable length, and fault resistance.

The results show that solidly earthed systems generally lead to the highest touch voltages, making them unfavorable from a personnel safety perspective, despite their good fault detection capability. In addition, the analysis highlights resonance phenomena between generator inductances and underground cable capacitances, which may cause overvoltages exceeding line-to-line voltage on healthy phases, increasing the risk of double earth faults. This behavior is particularly pronounced in isolated neutral systems, where no resistive damping is present.

The study concludes that impedance-earthed neutral systems offer the best compromise for isolated microgrids by limiting overvoltage risks, preserving personnel safety, and ensuring adequate earth-fault protection sensitivity.
Topic/s:
A10-Protection Issues for Hybrid Power Systems
Increasing Operational Flexibility of Existing Hydropower Through Non-Intrusive Monitoring, Feedback Control and Hybridization
Arvind Tiwari
GE Vernova, United States
Hydropower generators have long played a crucial role as a reliable and renewable source of electricity. However, hydro-operators typically limit flexible operation of a hydropower plant to limit operating in specific restricted operation zones, also referred to as ‘rough zones.’ Operating in ‘rough zones’ leads to hydropower unit vibration and wear and tear, causing hydropower operators limit operation in these zones, thereby restricting the flexibility hydropower plants can offer the power system. In this paper, we present novel innovative methodology that can increase operational flexibility of existing hydropower fleet throughout the world using a.) non-intrusive feedback monitoring, and b.) battery-hydro hybridization.

Firstly, this paper introduces the concept of Internet of Things (IoT) based non-intrusive monitoring and discusses its use in identifying ‘rough zones’ characterized by high vibrations. Secondly, leveraging the ‘rough zones’ information from non-intrusive monitoring, an optimal control strategy for a battery-hydro hybrid plant is designed to enable flexible operation in regions typically restricted for hydropower units. The results show the non-intrusive monitoring-based hydro-hybridization strategy not only helps hydropower units avoid operation in ‘rough zones’ but also improves overall plant flexibility and reduces the wear and tear.

The results from the studies conducted on an operational hydropower unit clearly demonstrate that the utilization of non-intrusive monitoring data within hydro-hybridization frameworks enables these plants to confidently operate in regions of their operational envelope that were traditionally considered off-limits due to concerns over mechanical stress and runner fatigue. By leveraging real-time feedback from cost-effective sensors and integrating this information with advanced control strategies, the proposed methodology provides a transformative enhancement in both the flexibility and efficiency of existing hydropower systems. This integration allows for dynamic adjustment of plant operations, ensuring optimal performance while simultaneously preserving asset health. The capability to identify and safely navigate previously “rough zones” not only reduces the risk of equipment damage but also expands the available dispatchable range, contributing to improved reliability and responsiveness of the system. Such improvements are particularly valuable in power networks with increasing penetration of intermittent renewable resources, where the need for adaptable, resilient generation assets is more pronounced. The hybridization of hydropower units with battery energy storage, guided by intelligent, non-intrusive monitoring and feedback control, supports more stable grid operations, facilitates load balancing, and enables rapid response to shifting demand profiles. Overall, the approach outlined in the study marks a significant advancement in hydroelectric asset management, making it possible to achieve greater operational efficiency and system reliability without the drawbacks of traditional, intrusive monitoring techniques. As renewable integration continues to grow, the adoption of these innovative methodologies will play a vital role in supporting the sustainable evolution of modern energy systems.

ACKNOWLEDGMENT - The authors would like to thank FirstLight Energy for providing access to their hydropower facility for the purpose of the data collection and for their valuable technical support throughout the project.

Acknowledgment and Legal Disclaimer (Abridged) included. The Recipient is required to include the following acknowledgement in publications arising out of, or relating to, work performed under this Award, whether copyrighted or not - ACKNOWLEDGMENT: This material is based upon work supported by the U.S. Department of Energy's Office of Energy Efficiency and Renewable Energy (EERE) under the Water Power Technologies Office (WPTO) Award Number DE-EE0010187. (ABRIDGED) LEGAL DISCLAIMER: The views expressed herein do not necessarily represent the views of the U.S. Department of Energy or the United States Government.
Topic/s:
B1-Hybrid Power Plant Technologies and Design
Design Considerations and Operating Experience of a High-Penetration Renewable Power Integration on Islanded Power Distribution System
Mohammad SEDIGHY
Hatch Ltd, Canada
Government of the Northwest Territories (NWT) in Canada has made a commitment to reduce Greenhouse Gas Emissions (GHG) through increasing the use of renewable energy and has targeted a reduction of GHG emissions through from electricity generation in off-grid communities by 25%, or 18 kilotonnes, below historical levels by 2030. The Town of Inuvik is the largest NWT’s off-grid community with a population of over 3000 which has historically relied on fossil fuel power for meeting its energy demand. The recently completed Inuvik hybrid power project involves the addition of a single 3.5 MW wind turbine which has a peak capacity covering most of the load demand. A 3.5 MW-2.8 MWh li-ion Battery Energy Storage System (BESS) has been also integrated to ensure reliable power delivery responding to dynamic variations in wind power output. In addition, a 1-MW PV power plant has been integrated in the community power grid as well. The renewable power integration has enabled offsetting the consumption of diesel fuel significantly. This paper describes the challenges associated in design and operation of a hybrid power system in islanded mode with high penetration of renewable power. Issues such as the impact of reduced fault levels on power distribution system protection with inverter-based resources (IBR), impact on supply of power to single-phase loads, operating the energy storage systems in grid following versus grid forming modes, and power system reliability considerations are discussed. These issues are equally important when designing grid-connected microgrids with ability to operate in islanded mode. In addition, the operating results after one full year of operation are discussed as well as future considerations to improve the hybrid power system performance.
Topic/s:
A6-Managing Variability and Uncertainty
Global Standards for Grid-Forming Inverters: Best Practices and Drafting Recommendations
Daniel Masendorf, Nis Martensen, Lucija Rakočević
Energynautics, Germany
In this presentation standards and guidelines for grid-forming inverters from different countries world wide are reviewed and compared. The analysis includes technical requirements as well as the procedure for proving compliance. Based on the review, clear recommendations for drafting new grid-forming guidelines are presented (e.g. for countries that do not have a standard yet). The importance of unambiguous wording, including functional, quantitative and dynamic requirements and the alignment with international best practices are highlighted. Finally, concrete texts for new guidelines, considering the before mentioned criteria, are suggested.
Topic/s:
A8-Standards and relevant Grid Codes for Hybrid Power Systems
Integration of Network Congestions in Long Term Planning - Strategies for Batteries Placement and Grid Reinforcement
Quentin Lebourg, Amine El Makhroubi, Hajar Kissi
EDF, France
Long‑term power system planning whether for large interconnected grids or for Non‑Interconnected Systems (NIS) traditionally relies on two separate processes: estimating the generation mix through hourly supply demand simulations, and assessing high‑voltage network flows to identify congestion and reinforcement needs. The complexity of combining these analyses generally prevents the use of a single unified model, making consistency between studies both necessary and difficult.

The accelerated deployment of renewable energy sources is reshaping this framework. In several NIS, electrical networks are approaching operational limits, increasing congestion risks. This new context requires a methodological shift in which long‑term planning integrates a coupled assessment of supply demand equilibrium and network constraints. Flexibility options such as strategic storage, local curtailment, and targeted reinforcements are then systematically evaluated to ensure robust planning and maintain coherence across prospective and power system studies.

The research proposes an integrated approach to NIS network planning, combining balancing studies with network analyses. Strategic storage is first sized to ensure supply–demand equilibrium and can also contribute to mitigating network constraints. If constraints persist, additional storage can be assessed and compared with conventional grid reinforcement to identify the most effective way to resolve remaining congestion.

The approach follows a sequence of successive steps. At each step, the placement and sizing of flexibilities are determined using an industrial optimization tool developed by EDF, dedicated to long-term and medium-term energy supply and demand balance studies for NIS power systems. This tool aims to calculate, over long- and medium-term horizons, operating generation plans that ensure the satisfaction of electricity demand while respecting both system and network constraints with an hourly resolution.

The model is formulated as a mixed-integer linear optimization problem, modeling production units through their installed capacities, technical limits, and availability. Demand trajectories and system service requirements (such as reserves) are enforced as constraints. The optimization ensures demand satisfaction and minimizes total operating costs in a context without market prices.

Beyond classical supply-demand formulations, the tool integrates a nodal high voltage network model coupling balance with the high-voltage grid. The network is represented by nodes and lines, using Power Transfer Distribution Factors (PTDF) matrices and maximum admissible flows on each line. This allows the tool to compute optimal solutions that are simultaneously feasible from a supply-demand balance and from a network perspective including the system resilience on any N-1 line contingency.

First non-decisional tests were conducted on Guadeloupe’s network, followed by an application for La Réunion‘s grid, focusing on renewable integration within a long term, ten year-horizon.

Findings highlight that this integrated methodology marks a major step forward in NIS planning. By embedding network constraints early in the design process and rigorously assessing tailored flexibility solutions, it reinforces coordination between supply–demand and reinforcement studies. This shift improves system resilience and provides a replicable framework for managing high‑RES challenges in NIS.
Topic/s:
A3-System Modelling and Simulation
Electrolyzers in Low-Inertia Power Systems: Modeling, Control, and Ancillary Service Provision
Jonathan Riofrio1, Shi You1, Tilman Weckesser1, Helma Maria Tróndheim2, 3
1 DTU – Technical University of Denmark, Denmark
2 Power Company Sev, Faeroe Islands
3 University of the Faroe Islands, Faeroe Islands
The integration of large-scale electrolyzers into modern power systems offers a promising solution to stability challenges from high renewable penetration. This paper presents a scalable modeling and control framework for grid-connected electrolyzers, linking electrochemical dynamics with system-level behavior. Detailed models of alkaline and proton exchange membrane electrolyzers are developed and scaled in DIgSILENT PowerFactory, featuring nested converter controls for droop-based active and reactive power support. Validation includes cell benchmarking, infinite-bus tests, and one of the first real-world grid simulations for electrolyzers using the Faroese bulk grid, demonstrating that electrolyzers can enhance frequency response and voltage support, acting as proactive stability assets in low inertia systems.
Topic/s:
A15-Hydrogen and Hybrid Power Systems
Supporting Caribbean Utilities: A Technical Assessment of PV Integration in Island Grids
Hannah Rühle, Victor Breburda, Alice Turnell, Pia Henzel
Energynautics, Germany
Caribbean island states target ambitious RE goals of e.g. 50% by 2030, yet current RE shares remain low with diesel as the main generation source. This "Solar Photovoltaic Integration Study" utilizes a multi-phase approach—combining PyPSA dispatch analysis with ETAP/PowerFactory electrical modelling—to assess the impacts of increasing PV integration across seven Caribbean utilities.

Key findings reveal that system-level limits are reached much earlier than feeder-level hosting capacity. The Minimum Stable Load (MSL) of synchronous generators (often fixed at 50-70% in contracts) and take-or-pay PPA agreements act as primary bottlenecks, creating little room for further PV expansion. Additionally, uncoordinated planning and independent feasibility studies can lead to significant overcapacity.

To guide successful RE integration, the study recommends a roadmap for unlocking flexibility: revisiting maintenance contracts to reduce the MSL, adding storage incrementally to provide reserves, and ultimately deploying grid-forming capabilities and install further technologies such as synchronous condensers to support grid stability with high RE shares.
Topic/s:
A2-Project Experience and Case Studies
Caribbean Grid Code Harmonization: A Regional Approach
Nis Martensen, Pia Henzel, Thomas Ackermann
Energynautics, Germany
TBD
Topic/s:
A8-Standards and relevant Grid Codes for Hybrid Power Systems
Synergy of Grid-Forming BESS and DSM Algorithms in Islanded Electric Systems: The Case of Lampedusa
Rossano Musca, Gaetano Zizzo
University of Palermo, Italy
This paper proposes a coordinated control framework that establishes synergy between grid-forming battery energy storage systems and demand side management, to improve both dynamic stability and resource endurance in hybrid island electric systems. The grid-forming battery delivers fast active power support, while demand side management provides slower but sustained flexibility, compensating persistent imbalances and preserving battery headroom. A hierarchical control strategy based on time-scale separation and supervisory coordination is developed, where demand modulation is driven by the sustained battery effort and its state of charge. The approach is validated through a 24-hour dynamic simulation of the Lampedusa island power system. Results show improved frequency performance and a significant mitigation of battery state-of-charge excursions, demonstrating that coordinated demand flexibility effectively acts as a virtual energy buffer that extends grid-forming battery capabilities.
Topic/s:
A2-Project Experience and Case Studies
Shaping St. Helenas EV Charging Regulation for Improved Power System Reliability
Thomas Ackermann, Thorsten Schlößer
Energynautics, Germany
Shaping St. Helenas EV charging regulation for improved power system reliability.
Topic/s:
A8-Standards and relevant Grid Codes for Hybrid Power Systems
Modelling of Demand Side Management in PyPSA Using a Storage-Equivalent Approach
Rabea Sandherr, Victor Breburda, Thomas Ackermann
Energynautics, Germany
TBA
Topic/s:
A2-Project Experience and Case Studies
An Overview on the Power Grid of Sicily
Rossano Musca
University of Palermo, Italy
An Overview on the Power Grid of Sicily
Topic/s:
A2-Project Experience and Case Studies
Insights into the Corsican Power System and the Integration of RES
Gregoire PRIME1, Alberto Pagnetti2
1 EDF, France
2 EDF-SEI-Corsica, France
Insights into the Corsican Power System and the Integration of RES
Topic/s:
A2-Project Experience and Case Studies
Challenges in Grid Integration of BESS with Wind Power
Slavomir Seman1, Jie Xi2, Ravi Singh3, Jurgen Timpert3
1 Huawei Technologies, Digital Power, Germany
2 Huawei Technologies, Digital Power, Netherlands
3 DNV Netherlands B.V, Netherlands
The real implementation cases shows that top challenges in the integration of BESS + Wind utilizing hybrid control are related to grid code compliance at the connection point. In the most of the cases it is caused by not optimized split of control functionalities between Master Plant control, Follower controllers and Power Electronic Converters’ controllers. A modern Hybrid Plants are also expected to provide Grid Forming functionalities at the Point of Connection. Mainly ability to operate in an island mode and provide system restoration support during a black start. The other challenges are related to EMT and RMS simulation models especially to their availability and plausibility. Modelling of a hybrid power plant is becoming even more challenging when several OEMs are involved that are supplying simulation models developed on different approaches, which sometimes may cause certain inconsistencies in entire plant simulation model. This challenge can only be solved by higher level of standardization of plant simulations focusing on adaptation of simulation models by means of proper validations assuring sufficient fidelity and interoperability. Last, but not least are the challenges related to safe and reliable operation of Batteries as well as Battery Management (charge, balancing, cooling) those functionalities must be properly integrated into overall control and coordinated with the other plant control functionalities.
Topic/s:
B2-Project Experience and Case Studies
Simplifying Microgrid Decisions: From Modeling Complexity to Practical Design Choices
Jose Toro
UL Solutions, United States
The increasing adoption of hybrid microgrids, which integrate distributed generation, energy storage, and flexible loads, has substantially increased the complexity of system design, especially in islanded and weak-grid environments. Although advanced modeling tools offer detailed technical and economic insights, practitioners frequently struggle to translate this complexity into clear, actionable design decisions.

This presentation introduces a streamlined decision-making framework for hybrid microgrid development, emphasizing the use of modeling as a practical tool to enhance clarity. Rather than concentrating on detailed component-level analysis, the session presents a structured methodology for defining project objectives, identifying key constraints, exploring scenarios, and evaluating outcomes in a consistent and transparent manner.

Behind-the-meter (BTM) and front-of-the-meter (FTM) applications serve as conceptual references to demonstrate how varying value frameworks influence microgrid design priorities. BTM applications are generally motivated by load optimization, cost reduction, resilience, and reliability requirements. In contrast, FTM applications are primarily associated with market participation, grid services, and revenue variability. This distinction underscores the importance of clearly defining project objectives and operating context prior to detailed system optimization.

The discussion is tailored for system planners, developers, and stakeholders engaged in microgrid and island contexts, where uncertainty, resource variability, fuel dependency, and reliability requirements are critical factors. The objective is to equip attendees with a clear and accessible methodology for utilizing modeling tools to support practical design decisions, enhance project framing, and mitigate decision-making risk in hybrid microgrid deployments.
Topic/s:
A3-System Modelling and Simulation
Best Practices and Lessons Learned from Italian and European Islands
Riccardo Novo
Clean energy for EU islands secretariat (3E), Italy
Best Practices and Lessons Learned from Italian and European Islands
Topic/s:
A2-Project Experience and Case Studies
Financial Benefits: Can RE-Developers Buy Local Acceptance?
Monika Bucha
Kelso Institute Europe Berlin, Germany
Financial Benefits: Can RE-Developers Buy Local Acceptance?
Topic/s:
A2-Project Experience and Case Studies
Overview of the Sardinian Power System
Matteo Contu, Cosimo Pisani
Terna S.p.A., Italy
Overview of the Sardinian Power System
Topic/s:
A2-Project Experience and Case Studies
Lessons Learned from an EMS-driven Optimisation in a Large Islanded Grid (Curaçao, Caribbean)
Johan Ågren, Sergio Motta
Wärtsilä Finland Oy, Finland
Lessons Learned from an EMS-driven Optimisation in a Large Islanded Grid (Curaçao, Caribbean)
Topic/s:
A2-Project Experience and Case Studies
Workshop Welcome & Introduction
Thomas Ackermann
Energynautics, Germany
Workshop Welcome & Introduction
Topic/s:
A2-Project Experience and Case Studies
Sardinian Island Towards 100% RES Target: Risks and Opportunities
EMILIO GHIANI
University of Cagliari, Italy
Partnership Models for Hybrid Power Adoption in Island Communities: Sardinian Island towards 100% RES Target: risks and opportunities
Topic/s:
A2-Project Experience and Case Studies